Appendix C

INITIAL HEIGHT SENSING CONNECTIONS

NOTE:

If using Command THC refer to Instruction manual # 802780

See page 3-8 for connections to power supply and IHS console. See Fig. c-1 for typical IHS connections.

IHS Interface Cable – Power Supply to IHS

14

8X1

Power Supply End

IHS End

1X9

1X9

8X1

Color

Signal

1

1

Red

IHS Complete Sig

4

4

Black

IHS Complete Com

8

Shield

Drain

2

2

Green

Upper Limit Sw Sig

5

3

Black

Upper Limit Sw Com

9

5

Shield

Drain

11

9

Black

AC Power

14

8

White AC

Power

7

Shield

Drain

7

Key

8X2/8X3

8X4/8X5

Color

Signal

4

A

Red

Power (+15 VDC)

2

B

Black

Common

1

C

Clear

Signal

3

Braid

Shield

14

Part No.

Length

023859

25 ft (7.6m)

023860

50 ft (15m)

023861

75 ft (23m)

023862

100 ft (30.5m)

023863

150 ft (46m)

023864

200 ft (61m)

IHS Sensor cables – IHS to Inductor Probes

The two sensor cables are components of the interconnecting leads for the inductive IHS system – see page c-4.

Part No.

Length

023888

2 ft (.6 m)

023869

40 ft (12 m)

Part No.

Length

023889

2 ft (.6 m)

023870

40 ft (12 m)

8X2

8X3

8X4

8X5

14A

14A