OPERATION

HySpeed HT2000LHF

Instruction Manual

4-5

6

Turn Power Supply On and Adjust Voltage/Current

6. Set the main disconnect switch for the power supply to the On position. See

Status Indicators Before Startup

.

Depress the POWER ON (I) button on the power supply. Ensure that the green POWER ON indicator on the

power supply illuminates.

7. Set the VOLTAGE and CURRENT on the Digital Remote. Select the arc current and arc voltage from the

Cut Charts

for the type and thickness of metal to test cut.

Adjust Preflow Gases

8. Set S2 toggle switch to Test Preflow . Verify that the plasma gas pressure gauges on the gas console both

read 120 psi (8.3 bar).

9. Look at FM1 and/or FM2 and set the Preflow plasma gas flow rate. Refer to the

Cut Charts

for flow rate

percentage.

10. Look at PG3 on the gas console, and set the Shield gas flow rate. Refer to the

Cut Charts

for flow rate

percentage.

Adjust Cut Flow Gases and Check Initial Height Sensing (IHS)

11. Set S2 toggle switch to Test Cut Flow.

12. Look at FM1 and/or FM2 and set the Cut Flow plasma gas flow rate. Refer to the

Cut Charts

for flow rate

percentage.

13. Set S2 to Run after setting the preflow and plasma flow rates.

14. Check the pilot arc operation by positioning the torch a minimum of 3 inches (75 mm) above the work.

15. Depress the START button. After 2 seconds of gas preflow, the primary contactor will close and the pilot arc

will start. The pilot arc should emit a steady, hissing sound and a cone of light should appear at the face of the

torch nozzle. The pilot arc will continue for approximately 300ms (O

2

) and 600 ms (Air/N

2

) and then extinguish

automatically.

16. Place the workpiece on the work table to make a test pierce. With manual starting, no machine motion will

occur.

Note: The cutting machine must retract the torch at least 1 inch (25.4 mm) from the work before the start

cycle, or probes may hit the workpiece when the START button is depressed.

17. Depress the START button. The IHS probes will immediately descend and approximately 0.5 seconds later, the

torch will move toward the workpiece. The DOWN indicator lamp on the Digital Remote should be illuminated.

When the torch nears the workpiece, the probes will inductively detect the work surface and the down motion

should stop. The DOWN indicator lamp on the Digital Remote will extinguish and the probes will retract.

At this point, depress the STOP button and disable the IHS system. You are now ready for the Final Torch

Adjustment.