MAINTENANCE

HySpeed HT2000LHF

Instruction Manual

5-17

6

Figure 5-7

Plumbing Schematic of Power Supply Reservoir Assembly and Torch

Cathode Block

(in back of

power supply)

Heat

Exchanger

Check

Valve

Flow Switch

FS1

Solenoid Valve

V1

Particulate

Filter

Float Switch

LS1

Coolant Reservoir

Temperature Switch

TS1

Torch

Pump with

Relief Valve

Torch Coolant Draining

Hypertherm recommends draining the torch coolant from the power supply and torch before transporting the

system. After this draining procedure, a small amount of coolant will remain in the system pump and valves. For

this reason, Hypertherm also recommends that a suitable ratio of propylene glycol be purged through the system

prior to draining if the system will experience extremely cold temperatures. Note that Hypertherm's stock propylene

glycol solution 028872 is rated to 10° F (-12° C).

1. Disconnect all power to the system.

2. Remove the fill inlet cap from the reservoir to allow proper venting.