Specifications – Hypertherm HT200LHF-200 Volt HySpeed User Manual

Page 29

Advertising
background image

SPECIFICATIONS

2-2

HySpeed HT2000LHF

Instruction Manual

7

Remote Current Control Console

This unit contains a manually adjustable thumbwheel to set arc current only.

Initial Height Sensing - Optional

This unit, used with 2 inductive probes, is designed to automatically detect the workpiece surface and move the

torch to the pierce position. This system can be used for underwater cutting, cutting at the water line, or cutting

above water.

Timer/Counter – Optional

The timer/counter allows the operator to monitor the number of arc starts and the cumulative time that the arc is on

in hours. The arc starts can be reset.

Water Muffler – Optional

The water muffler for the LHF system is an option which greatly improves cutting safety and pollution control

capabilities. The water muffler can be used to cut above, below and at the water line. Refer to the Water Muffler

instruction manual 802050 for more detailed information. The water muffler cannot be used with the stainless steel

torch.

CommandTHC – Optional

The CommandTHC is an external torch height control and initial height sensing system designed for plasma cutting

applications on an x-y cutting table. Refer to the CommandTHC instruction manual 802780 for more detailed

information.

Specifications

System Requirements

Power Requirements:

Refer to LHF power supply specifications below:

Gas Requirements:

Plasma Gas Types........................................................Oxygen, Nitrogen, Air,

Argon-Hydrogen (H35 = 35% Hydrogen/ 65% Argon)

Shield Gas Types..........................................................Air, Nitrogen, Carbon Dioxide

Gas Quality:

Oxygen .........................................................................99.5% pure (liquid gas recommended)

Nitrogen ........................................................................99.995% pure (liquid gas recommended)

Air .................................................................................Clean, dry, oil-free (compressed or liquid gas recommended)

Carbon Dioxide .............................................................99.5% pure (compressed or liquid gas recommended)

Plasma Gas Inlet Pressures and Flow Rates:

Air .................................................................................90 psi +/- 10 psi (6.2 bar +/- 0.7 bar) at 82 scfh (2322 l/h)

Oxygen .........................................................................120 psi +/- 10 psi (8.3 bar +/- 0.7 bar) at 90 scfh (2549 l/h)

Nitrogen ........................................................................120 psi +/- 10 psi (8.3 bar +/- 0.7 bar) at 80 scfh (2265 l/h)

Argon-Hydrogen ...........................................................120 psi +/- 10 psi (8.3 bar +/- 0.7 bar) at 105 scfh (2973 l/h)

Shield Gas Inlet Pressures and Flow Rates:

Air .................................................................................90 psi +/- 10 psi (6.2 bar +/- 0.7 bar) at 280 scfh (7929 l/h)

Carbon Dioxide .............................................................90 psi +/- 10 psi (6.2 bar +/- 0.7 bar) at 220 scfh (6230 l/h)

Nitrogen ........................................................................90 psi +/- 10 psi (6.2 bar +/- 0.7 bar) at 275 scfh (7787 l/h)

Oxygen .........................................................................120 psi +/- 10 psi (8.3 bar +/- 0.7 bar) at 35 scfh (991 l/h)