Warning – Hypertherm HT200LHF-200 Volt HySpeed User Manual

Page 45

Advertising
background image

1X1

INSTALLATION

3-12

HySpeed HT2000LHF

Instruction Manual

6

Note: If you are using a machine computer interface to set voltage and current and do not want the programmable

voltage current readout, skip references 7-9.

Remote Voltage and Current Cable – Power Supply to Digital Remote or Programmable Remote

1x4

5x1

Color

Signal

4

1

Green

SID Data

8

2

Black

SID Common

13

Grn/Blk

Shield

9

3

Red

SOD Data

15

6

Black

SOD Common

14

Red/Blk

Shield

35

7

White

AC Power

36

8

Black

AC Power

31

Wht/Blk

Shield

5

Key

22

Key

6

6

Notes: •

If using this Remote I/O Cable, remove jumpers from power supply
TB5 terminals 1&2 and 4&5 and terminate Remote I/O Cable wires for
PB2A and PB2B to a normally closed switch.

• Terminate wires for PB1A and PB1B to a normally open switch.
• Input requirements for interlocks: DC current between 15 and 20 mA; DC

voltage between 12 and 15 V.

• Refer also to pages 3 and 6 of the wiring diagrams in Section 7.

Remove jumper

Remove jumper

7

7

1X4

5X1

Part No.

Length

123294

6 ft (1.8 m)

123295

15 ft (4.6 m)

123296

25 ft (7.6 m)

123297

35 ft (10.7 m)

123298

50 ft (15.3 m)

123299

60 ft (18.3 m)

123300

75 ft (23 m)

Part No.

Length

123301

85 ft (25.9 m)

123302 100 ft (30.5)

123303 115 ft (35.1 m)

123304 120 ft (36.6 m)

123305 125 ft (38.1 m)

123306 150 ft (46 m)

123307 200 ft (62 m)

Remote I/O Cable – Power Supply to Remote Interface

1x1

Color

Signal

19

White

FS1 Interlock

20

Red

FS1 Interlock

13

Shield

Ground

23

Blue

LT1 120 VAC

24

Black

LT1 120 VAC

25

Shield

Ground

26

Red

PB2A 24 VAC

27

Green

PB2A 24 VAC

28

Shield

Ground

29

White

PB2B 120 VAC

30

Black

PB2B 120 VAC

34

Shield

Ground

32

Brown

PB1A 24 VAC

33

Black

PB1A 24 VAC

37

Shield

Ground

35

Red

PB1B 120 VAC

36

Brown

PB1B 120 VAC

31

Shield

Ground

1x1

Color

Signal

2

Yellow

PB1 LT1 24VAC

3

Black

PB1 LT1 24VAC

7

Shield

Ground

5

Orange

TS1 Interlock

6

Black

TS1 Interlock

1

Shield

Ground

8

Red

LS1 Interlock

9

Black

LS1 Interlock

4

Shield

Ground

11

Green

PS3 Interlock

12

Black

PS3 Interlock

18

Shield

Ground

14

Red

PS1,PS2 Interlock

15

Blue

PS1,PS2 Interlock

21

Shield

Ground

16

Red

TS2 Interlock

17

Yellow

TS2 Interlock

10

Shield

Ground

Part No.

Length

023990

7 ft (2.1 m)

023911

15 ft (4.6 m)

023878

25 ft (7.6 m)

023879

50 ft (15.3 m)

123040

60 ft (18.3 m)

023880

75 ft (22.9 m)

123073

85 ft (25.9 m)

023881

100 ft (30.5 m)

Part No.

Length

123188

120 ft (36.6 m)

023882

125 ft (38.1 m)

023883

150 ft (45.8 m)

023884

200 ft (61 m)

023885

250 ft (76.3 m)

023886

275 ft (83.9 m)

023887

300 ft (91.5 m)

WARNING

• Be certain to properly terminate 120 VAC wire connections!
• Provide proper strain relief for remote I/O cable at customer interface.