Digital remote voltage & current control console, Remote current control console – Hypertherm HT200LHF-200 Volt HySpeed User Manual

Page 32

Advertising
background image

SPECIFICATIONS

HySpeed HT2000LHF

Instruction Manual

2-5

6

Digital Remote Voltage & Current
Control Console

Controls....................Voltage adjust potentiometer: Adjusts arc

cutting voltage and displays value on LEDs.

Current adjust potentiometer: Adjusts arc

current and displays value on LEDs.

Control range ...........Current: 40-200 amps/Voltage: 100-200 volts

Control resolution.....Current: 10 amps/ Voltage: 5 volts

Dimensions and Weight:

Width .......................................................11.4" (290 mm)

Height......................................................3" (76 mm)

Depth.......................................................13.4" (340 mm)

Weight .....................................................5.3 lbs (2.4 kg)

Programmable Remote Voltage & Current
Control Console

Controls....................None. Controlled through guidance CNC.

Control range ...........Current: 40-200 amps/Voltage: 100-200 volts

Control resolution.....Current: 10 amps/ Voltage: 5 volts

Dimensions and Weight:

Width .......................................................11.4" (290 mm)

Height......................................................3" (76 mm)

Depth.......................................................12.5" (318 mm)

Weight .....................................................5.3 lbs (2.4 kg)

Remote Current Control Console

Dimensions and Weight:

Width .......................................................6-1/2" (165 mm)

Height......................................................2-1/2" (64 mm)

Depth.......................................................8-5/8" (219 mm)

Weight .....................................................3 lbs (1 kg)

10.5" (267 mm)

11.4" (290 mm)

7/32"

(5.5 mm)

dia.

4 places

11.65" (296 mm)

5"

(127 mm)

0.5"

(13 mm)

Figure 2-4

Mounting Dimensions – Digital

Remote Voltage & Current Control Console

10.5" (267 mm)

11.4" (290 mm)

7/32" dia.

(5.5 mm)

4 places

11.65" (296 mm)

5"

(127 mm)

0.5"

(13 mm)

Figure 2-5

Mounting Dimensions – Programmable

Remote Voltage & Current Control Console

Figure 2-6

Mounting Dimensions –

Remote Current Control Console

5/32" ø (4 mm) – 4 places

3.38" (86 mm)

6.25" (159 mm)

8.5" (216 mm)

0.50" (13 mm)

1.17"

(30 mm)

6.50"

(165 mm)

Advertising
This manual is related to the following products: