MAINTENANCE

5-8

HySpeed HT2000LHF

Instruction Manual

6

Problem

Possible Causes

/ Solutions

5.2. Pilot arc relay CR1 is defective.

If there is 120VAC across the relay (see previous steps),

and CR1 does not close, replace CR1.

5.3. Main contactor (CON1) or PCB4 is defective.

• With an AC voltmeter, see if there is 120VAC at contactor

CON1 after the START command is given. If there is no

120VAC, check pins, connectors and associated wiring

from CON1 to PCB4.

• If wiring is OK, PCB4 or PCB2 may be defective.

• If there is 120VAC at CON1 as described above, measure

the voltage between secondary terminals of the main

transformer T2 after the START command is given. The

voltage between any two of the three points connected to

each chopper input should be equal to about 200VAC.

If there is no voltage at any of the above points, replace

CON1.

If there is voltage at some but not all of the above points,

check wiring and connections to and from T2. If wiring

checks out OK, return to Initial Checks section and repeat

steps 1-5.

5.4. Choppers are defective or not functioning.

See

Chopper Module Test Procedure l

ater in this section.

6. The unit stops cutting during cut, or

cuts poorly.

6.1. The work cable is not connected or it is broken.

Connect or repair the work cable.

6.2. Arc not transferring to workpiece.

Check the work cable connection to the workpiece. Good

contact must be made in order for the arc to transfer.

6.3. There is insufficient air or gas pressure.

Check the gas inlet pressures and the plasma and shield

gas pressures in TEST and RUN modes as specified in the

Cut Charts.

6.4. Torch is getting insufficient current.

Check the arc current setting in the

Cut Charts

for the type

and thickness of metal you are cutting.

6.5. The power supply has overheated.

Shut down the system and wait for the power supply to cool

down. If the power supply will not restart, see

Status LED

Troubleshooting

guide later in this section.

6.6. Choppers are defective or not functioning.

See

Chopper Module Test Procedure

later in this section.