Replacement – Hypertherm HT200LHF-200 Volt HySpeed User Manual

Page 85

Advertising
background image

OPERATION

4-32

HySpeed HT2000LHF

Instruction Manual

7

Replacement

1. Before installing the electrode, be sure to lubricate the O-ring lightly with a very thin film of the lubricant

provided in the consumable parts kit. Replace the electrode and tighten it with the wrench.

Do not

overtighten

.

2. Before installing the swirl ring, be certain to lubricate the O-rings lightly with a very thin film of the lubricant

provided in the consumable parts kit. Install the swirl ring with the bottom O-ring facing the inside of the

torch. Push it into place. Be sure to hold the swirl ring in place until the nozzle is installed to avoid dropping

it into the water of the water table.

3. Install the nozzle and tighten by hand. Finish tightening it with the wrench.

Do not overtighten

4. Screw on the shield to the retaining cap and tighten by hand. Screw on the retaining cap to the torch and

tighten by hand. Make sure that it is tightened snugly; if it is loose, it can affect the shield gas flow.

Figure 4-7

Changing Consumable Parts

Shield

Retaining cap

Nozzle

Swirl ring

Electrode

Current ring

O-rings

Water tube

Torch body

(shown without off valve SA and sleeve)