Appendix A

ARGON-HYDROGEN CUTTING AND GOUGING

Introduction

This section contains installation and operation information for cutting and gouging using argon-hydrogen as the

plasma gas.

• See

Installation

to make the remaining power supply and gas console connections.

Do not use the water muffler when cutting with argon-hydrogen!

MV1

Adjusts argon-hydrogen plasma gas flow rate

% in Test/Preflow mode. Preflow plasma gas

flow rate percentages are specified in the

Argon-Hydrogen Cut Charts

.

FM1

Indicates the argon-hydrogen plasma

gas flow rate %. Flow rates for

argon-hydrogen are specified in the

Argon-Hydrogen Cut Charts

.

Figure a-1

Argon-Hydrogen Manifold Front Panel Controls and Indicators

Argon-Hydrogen Manifold FRONT PANEL CONTROLS and INDICATORS
(Fig. a-1)

Installation

WARNING

Before operating the argon-hydrogen manifold, turn all power and gases connected to the system OFF.
Follow the installation and operation procedures before turning power and gases ON.