Power cable, Connect power cable – Hypertherm HT200LHF-200 Volt HySpeed User Manual

Page 190

Advertising
background image

APPENDIX D: ELECTROMAGNETIC COMPATIBILITY

d-2

HySpeed HT2000LHF

Instruction Manual

6

Power Cable

The power cable is

customer supplied

. See

Power Requirements

on page 3-4 for recommended cable sizes.

Final specification and installation of the power cord should be made by a licensed electrician and according to

applicable national or local codes. See also

Mains Supply

on page i for further power (supply) cable shielding

recommendations.

Connect Power Cable

Connect one end of the power cable to the EMI filter first and then connect the other end to the line disconnect

switch.

Power Supply

1. Locate the EMI filter on the top rear of the power supply (see Figure d-1).

2. Unscrew the 4 filter cover screws and remove the cover to access the input voltage connections at TB1 (see

Figure d-2).

3. Insert the power cable through the strain relief (see Figure d-1).

4. Connect leads L1 to U, L2 to V, and L3 to W terminals of TB1 (see Figure d-3). Ensure that all connections are

tight to avoid excessive heating.

5. Connect the ground lead to the terminal marked PE at TB1 (see Figure d-3).

Figure d-1

Hyspeed HT2000LHF Power Supply with EMI Filter – Side View

EMI Filter

Strain Relief

HySpeed HT2000LHF

Advertising
This manual is related to the following products: