SPECIFICATIONS

HySpeed HT2000LHF

Instruction Manual

2-3

6

Power Supply

Maximum OCV (U

0

) ......................................................280 VDC

Output Current (I

2

) ........................................................40 – 200 amps

Output Voltage (U

2

) ......................................................150 VDC

Duty Cycle Rating (X) ..................................................100% up to 30 kW. Beyond 30 kW, Duty Cycle (X) =

(30 kW/Actual Power)

2

Eg: If Actual Power = 32 kW, then Duty

Cycle (X) = (30 kW/32 kW)

2

= 88%

Ambient Temperatures/Duty Cycle ...............................Power supplies will operate between +14° and 104° F (-10° and

+40° C). Power supplies operated in an ambient temperature

above 86° F (30° C) may show some decrease in duty cycle.

Power Factor (cos

ϕ

) .....................................................0.86

Input Power

(Input Voltage (U

1

) x Input Current ( I

1

))

:

073227

with THC;

073228

without THC .......................200 VAC, 3PH, 50 Hz, 108 amps

073229

with THC;

073230

without THC .......................208 VAC, 3PH, 60 Hz, 104 amps

073231

with THC;

073232

without THC .......................240 VAC, 3PH, 60 Hz, 90 amps

073235

with THC;

073236

without THC .......................400 VAC, CE, 3PH, 50 Hz, 56 amps

073262

with THC;

073263

without THC .......................440 VAC, 3PH, 50-60 Hz, 49 amps

073233

with THC;

073234

without THC .......................480 VAC, 3PH, 60 Hz, 45 amps

073237

with THC;

073238

without THC .......................600 VAC, 3PH, 60 Hz, 36 amps

Dimensions and Weight:

Width.............................................................................28-1/4" (710 mm)

Height ...........................................................................35-1/2" (900 mm); 40-3/4" (1035 mm) on CE units

Depth ............................................................................41-1/4" (1045 mm)

Weight...........................................................................780 lbs (351 kg); 800 lbs (363 kg) on CE units

Cooling..........................................................................Forced Air (Class F)

Coolant Tank Capacity..................................................2.9 gallons (11 liters)

Maximum cutting thickness...........................................2" (50 mm)

Maximum current at 100% duty cycle...........................200 amps

Plasma and Shield Gas Flow........................................Refer to the

Cut Charts

in the

Operation

section for specific gas

requirements.

Water coolant flow rate .................................................0.8 gpm (3.0 l/min)

Weight...........................................................................3 lbs (1.36 kg)

Figure 2-1

LHF Machine Torch

(standard torch shown. See Section 6 for figure of stainless steel torch)

6"

(152 mm)

15.4"

(391 mm)

23.25"

(590 mm)

2"

(51 mm)

4.3"

(109 mm)

2" (50 mm) or

1.75" (44 mm)

See Sect. 6

HySpeed LHF Machine Torch