Mild steel, Above water, 3" under water – Hypertherm HT200LHF-200 Volt HySpeed User Manual

Page 66: 200 amps • o, Plasma / air shield

Advertising
background image

OPERATION

HT2000LHF

Instruction Manual

4-13

6

Shield

Arc

Approx.

Material

Plasma Gas Flow Rate %

Gas (Air)

Torch-to-work

Initial Torch

Voltage

Motion

Thickness

Preflow

Cutflow

Pressure

Distance

Piercing Height

Setting

Travel Speed

Delay Time

(inches)

(mm)

(O

2

% N

2

%) (O

2

% N

2

%)

(psi)

(inches)

(mm)

(inches)

(mm)

(volts)

(ipm) (mm/min.)

(sec)

Shield

Arc

Approx.

Material

Plasma Gas Flow Rate %

Gas (Air)

Torch-to-work

Initial Torch

Voltage

Motion

Thickness

Preflow

Cutflow

Pressure

Distance

Piercing Height

Setting

Travel Speed

Delay Time

(inches)

(mm)

(O

2

% N

2

%) (O

2

% N

2

%)

(psi)

(inches)

(mm)

(inches)

(mm)

(volts)

(ipm) (mm/min.)

(sec)

1/4

6

5

45

64

0

60

1/8

3

1/4

6

120

160

4060

0.5

.315

8

(5.3 / 62.4 (79.6 / 0

(270

1/8

3

1/4

6

125

120

3000

0.5

3/8

10

SCFH)

SCFH)

SCFH)

1/8

3

1/4

6

125

100

2540

1.0

1/2

12

.157

4

.314

8

125

80

2030

2.0

5/8

15

.157

4

.314

8

130

70

1780

2.0

3/4

20

3/16

5

3/8

10

135

55

1400

2.5

7/8

22

1/4

6

1/2

12

135

45

1140

2.5

1

25

1/4

6

1/2

12

140

35

890

2.5

1-1/4

32

1/4

6

1/2

12

150

22

560

3.0

1-1/2

38

1/4

6

1/2

12

155

15

380

3.0

1-3/4

44

5/16

8

5/8

12

165

10

250

3.0

2

50

5/16

8

5/8

12

170

7

180

3.0

Mild Steel

200 amps • O

2

Plasma / Air Shield

This gas combination gives superior cut speed, minimum dross, minimum surface nitriding and excellent

weldability.

Above Water

1/4

6

5

45

64

0

70

1/8

3

1/4

6

125

145

3700

0.5

.315

8

(5.3 / 62.4 (79.6 / 0

(280

1/8

3

1/4

6

125

110

2800

0.5

3/8

10

SCFH)

SCFH)

SCFH)

1/8

3

1/4

6

130

80

2000

1.0

1/2

12

1/8

3

1/4

6

130

70

1800

2.0

5/8

15

.157

4

.314

8

135

60

1500

2.0

3/4

20

3/16

5

3/8

10

140

48

1200

2.5

7/8

22

1/4

6

1/2

12

140

38

950

3.0

1

25

1/4

6

1/2

12

145

25

680

3.0

3" Under Water

120833*

(cw)

120834

(ccw)

Swirl ring

020605
Nozzle

020423

(cw)

020955

(ccw)

Retaining cap

020424
Shield

120667 (standard)
Electrode
220084 (optional)
SilverPlus electrode

+

Notes:

Set oxygen plasma gas inlet pressure to 120 psi (8.3 bar).
Set nitrogen plasma gas inlet pressure to 120 psi (8.3 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)

Production cutting above 1" (25 mm) not recommended. Drop cutting above 1-1/2" (38 mm) not recommended

* Use 020679 swirl ring in place of 120833 swirl ring to obtain smoother cut edges on material

1/4" to 3/8" thick, but expect a 30-40% decrease in electrode life

+ SilverPlus provides increased life to high duty cycle users in most applications. The hafnium wears to

approximately twice the depth of a standard electrode (120667). Arc voltage may need to be increased by 5-10
volts throughout the electrode life to maintain proper cut height parameters.

Advertising