INSTALLATION

HySpeed HT2000LHF

Instruction Manual

3-7

6

Power Cable from LHF Power Supply to Power Source.

1.

Be certain that the line disconnect switch is in the OFF position and remains in the OFF position for the
remainder of the installation of the LHF system.

2. Connect the power cord leads to the line disconnect switch following local and applicable electrical codes.

Torch Lifter Requirements

The LHF system requires a high-quality, motorized torch lifter with sufficient travel to cover all cutting thickness

requirements. The lifter must provide

10 inches (254 mm) of vertical travel

. The unit should have a constant

speed of at least

20 ipm (508 mm/min)

with positive braking. A unit which drifts through the stop point is not

acceptable.

Optional Equipment

Water Muffler

Refer to Water Muffler instruction manual 802050. A power cable for the Water Muffler pump must be provided by

the customer. The pumps provided by Hypertherm take a three-phase input. Part numbers and corresponding

voltages are listed in the Water Muffler manual. Input current information is provided on the motor data plate.

Present pump systems all draw less than 20 amps and cable sizes should be selected accordingly.

The water muffler cannot be used with the stainless steel torch.

System Units Placement

• Position all required units prior to making electrical, gas and interface connections.

• Ground all external modules in the LHF system to earth.

• To prevent leaks in the system, tighten all gas and water connections to the following specifications:

Use 2 wrenches when tightening to prevent damage to the mating component.

Use the diagram on the following 2 pages to make system interconnections. Follow the number guide on the

diagram to find out specific information on each cable, hose or connection. The numbered items are detailed on the

pages following the interconnection diagram.

Gas or water

Torque Specification

hose size

lbf-in

lbf-ft

kgf-cm

up to 3/8"

75-85

6.25-7

86-98

1/2"

360-480

30-40

415-550