Warning – Hypertherm HT200LHF-200 Volt HySpeed User Manual

Page 44

Advertising
background image

1X7

1X6

INSTALLATION

HySpeed HT2000LHF

Instruction Manual

3-11

6

Machine V/C Interface Cable – Power Supply
to Machine Interface

1x6

Color

Signal

2

Yellow

Initial Height Sig. (OFF=Closed)

6

Black

Initial Height Com.

11

Shield

4

Orange

Auto Height Sig. (OFF=Closed)

8

Black

Auto Height Com.

13

Shield

34

Red

*†Lifter DOWN Load (DOWN=Closed)

29

Black

Lifter DOWN Line

23

Shield

35

Green

*†Lifter UP Load (UP=Closed)

30

Black

Lifter UP Line

24

Shield

36

Red

Upper Limit Switch ( OFF=Closed)

31

Blue

Upper Limit Switch

25

Shield

1x6

Color

Signal

9

Blue

Plasma START (START=Closed)

15

Black

Plasma START

14

Shield

37

Red

†Arc Transfer (TRANSFER=Closed)

32

Green

†Arc Transfer

26

Shield

1

White

Hold Ignition Sig. (HOLD=Closed)

5

Black

Hold Ignition Com.

10

Shield

3

Brown

Ramp Down Error

7

Black

Ramp Down Error

12

Shield

1x7

Color

Signal

2

White

Current 10

3

Red

Current 20

4

Green

Current 40

5

Orange

Current 80

6

Blue

Current 100

7

White/Black

Current 200

10

Shld

Shield

11

Blue/Black

Current Common

1x7

Color

Signal

16

Black/Red

Voltage V5

17

White/Red

Voltage V10

18

Orange/Red

Voltage V20

19

Blue/Red

Voltage V40

20

Red/Green

Voltage V80

21

Orange/Green

Voltage V100

22

Black/White/Red

Voltage V200

23

White/Black/Red

Voltage VCommon

Part No.

Length

023841

6 ft (1.8 m)

023842

15 ft (4.6 m)

023843

25 ft (7.6 m)

023844

35 ft (10.7 m)

023845

50 ft (15 m)

123047

60 ft (18.3 m)

023846

75 ft (23 m)

Part No.

Length

123080

85 ft (25.9 m)

023847

100 ft (30.5)

023962

115 ft (35.1 m)

123148

120 ft (36.6 m)

023848

125 ft (38.1 m)

023849

150 ft (46 m)

023850

200 ft (62 m)

4

4

5

5

* Signals are AC relays. DC relays are available as an option from Hypertherm by ordering kit: 128404

Machine I/O Interface Cable – Power Supply
to Machine Interface

Part No.

Length

023902

6 ft (1.8 m)

023851

15 ft (4.6 m)

023852

25 ft (7.6 m)

023853

35 ft (10.7 m)

023854

50 ft (15 m)

Part No.

Length

023855

75 ft (23 m)

023856

100 ft (30.5)

023903

125 ft (38.1 m)

023857

150 ft (46 m)

023858

200 ft (62 m)

WARNING

When installing or servicing the power supply, AC or DC line voltages may be present on the UP,
DOWN and TRANSFER signals even if the power supply line disconnect switch is OFF. Make certain
that all line disconnect switches relating to the system are OFF during installation and when servicing.

Note:

If you are using a remote V/C to set voltage and current, skip this step.

Before connecting the machine V/C interface cable, see the wiring diagrams in this manual and verify that

the correct plug is attached to the µP control PCB REC6 receptacle.