System checkout – Hypertherm HT200LHF-200 Volt HySpeed User Manual

Page 57

Advertising
background image

OPERATION

4-4

HySpeed HT2000LHF

Instruction Manual

6

Timer/Counter

STARTS

LCD Counter (w/Reset)

Indicates the number of arc starts

ERRORS

LCD Counter (w/Reset)

Indicates the number of times that the arc cut

cycle ended before the programmed current

ramp-down time had elapsed. This reading

provides a direct correlation to the long-life

operation of the electrode; the higher the

reading, the shorter the electrode life.

Reset

ARC TIME

LCD Counter

Indicates the cumulative time

that the arc is on in hours.

Reset

Figure 4-6

Timer/Counter Front Panel Controls

System Checkout

The following procedure assumes the plasma system includes an IHS system, a Digital Remote (DR) Voltage &

Current Control Console, and the optional internal THC.

Set Switches and Check Torch

1. Ensure that the switches listed below are positioned as follows:

The main disconnect switch for the power supply is set to Off.

S2 toggle switch on the gas console is set to Run

.

2. Ensure that the proper consumables are installed in the torch. Refer to the

Cut Charts

to choose the correct

consumables for your cutting needs. See also

Changing Consumable Parts

at the end of this section.

3. Ensure that the torch is squared to the material. Refer to

Section 3

for the torch alignment procedure.

Turn Gases On

4. Set S1 toggle switch on the gas console to N

2

/Air or O

2

.

5. Turn the required supply gases On.

• When using oxygen, or nitrogen as the plasma gas, adjust supply regulator to read 120 psi +/- 10 psi

(8.3 bar +/- 0.7 bar).

When using air as the plasma gas, adjust supply regulator to read 90 psi +/- 10 psi (6.2 bar +/- 0.7 bar).

• Adjust the supply regulator for shield gas to read 90 psi +/- 10 psi (6.2 bar +/- 0.7 bar).