Coolant flow test procedure – Hypertherm HT200LHF-200 Volt HySpeed User Manual

Page 104

Advertising
background image

MAINTENANCE

HySpeed HT2000LHF

Instruction Manual

5-15

6

Coolant Flow Test Procedure

If the COOLANT FLOW Status LED illuminates, verify that the proper flow is maintained by following the

troubleshooting sequence outlined in this procedure:

Check Reservoir Coolant

1. Shut off the power supply.

2. Remove the torch coolant reservoir cap.

3. Remove the power supply rear cover.

4. Verify that the reservoir is full of coolant. Add coolant, if necessary.

Verify Flow Rate Return from Torch

1. Find a clean 1-gallon (3.8 liter) container.

2. Locate the two coolant hoses that come off of the cathode block at the rear of the power supply (black hoses:

one with a green tape band and one with a red tape band – See Fig. 5-6).

3. Remove the torch coolant return hose (black hose with the red band) from the cathode block.

4. Place the red banded hose into the 1-gallon container.

WARNING

Push the OFF (0) button on the power supply and place the main disconnect switch in the OFF
position before proceeding.

Torch Coolant Supply Hose
(Black with Green Band)

Cathode Block

Torch Coolant Return Hose
(Black with Red Band)
Remove this hose

Figure 5-6

Torch Coolant Supply and Return Hoses

Advertising
This manual is related to the following products: