Hyspeed, Ht2000lhf, Gas console – Hypertherm HT200LHF-200 Volt HySpeed User Manual

Page 55

Advertising
background image

PLASMA

N

2

/Air

O

2

SHIELD

N

2

/Air

psi

psi

psi

DC

N

2

/Air

O

2

O

2

PLASMA

Cut Flow

PreFlow

PreFlow

Run

10

9

8

7

6

5

4

3

2

1

0

10

9

8

7

6

5

4

3

2

1

0

Test

Preflow

Test

Cutflow

HySpeed

®

HT2000LHF

®

OPERATION

4-2

HySpeed HT2000LHF

Instruction Manual

6

Gas Console

Figure 4-2

LHF Gas Console Front Panel Controls and Indicators

S2

Test Preflow –

Used when setting the

plasma preflow flow rate on the flowmeter. In

this position the contactor is disabled.

Test Cut Flow –

Allows the selected plasma

gas flow rate to be adjusted on the flowmeter

for cutting conditions. In this position the

contactor is disabled.

Run –

Enables the contactor and the

subsequent firing of the arc after the gas

rates have been set in the

Test Preflow

and

Test Cut Flow

positions.

LT1

Illuminates when the main

contactor closes, indicating

that DC power is being

supplied to the torch.

FM1

Indicates the flow rate % of nitrogen or air

plasma gas. Percentages are specified in the

Cut Charts

.

PG1

Indicates the nitrogen or air plasma inlet

pressure. Gas inlet pressures are specified

in the

Cut Charts.

FM2

Indicates the flow rate % of

oxygen plasma gas.

Oxygen flow rate percent-

age is specified in the

Cut Charts

.

PG2

Indicates the oxygen plasma

inlet pressure. Gas inlet

pressures are specified in the

Cut Charts

.

MV1

Adjusts flow rate % of nitrogen,

air or oxygen plasma gas while

in

Test Cut Flow

mode. Cut

Flow plasma gas flow rate

percentages are specified in the

Cut Charts

.

S1

Selects the use of either nitrogen,

air or oxygen as the plasma cutting

gas.

MV2

Adjusts flow rate % of nitrogen,

or air plasma gas while in the

Test Preflow

mode. Preflow

plasma gas flow rate percent-

ages are specified in the

Cut Charts

.

MV3

Adjusts flow rate % of oxygen plasma gas

while in

Test Preflow

mode. Preflow

plasma gas flow rate percentages are

specified in the

Cut Charts

.

PG3

Indicates the shield gas

pressure at the torch.

MV4

Adjusts shield gas pressure

to the torch.

Designations

FM1-FM2 –– Flowmeters

LT1 –– Indicator Lamp

MV1-MV3 –– Motor Valve

PG1-PG3 –– Pressure Gauges

S1-S2 –– Toggle Switch