APPENDIX A: ARGON-HYDROGEN CUTTING AND GOUGING

a-4

HySpeed HT2000LHF

Instruction Manual

6

Figure a-5

Nitrogen Supply to Gas Console

Nitrogen supply to Gas Console

• Connect the nitrogen supply to the shield connection at the rear of the gas console. (Figure a-5)

Ni

trogen

2WRENCHES

4. Connect the left-hand threaded connector

015049 to the torch plasma gas hose.

5. Attach one end of the argon-hydrogen

plasma gas torch lead to the plasma gas

torch lead connection located on the front

of the argon-hydrogen manifold.

(Figure a-4)

6. Attach the other end of the argon-

hydrogen plasma gas torch lead to the

015049 connector.

Plasma gas torch lead
connection

015049
connector

Torch
plasma gas
hose

Argon-hydrogen plasma gas
torch lead

Figure a-4

Converting the HT2000LHF Torch for Argon-Hydrogen Cutting – 2 of 2