INSTALLATION

HySpeed HT2000LHF

Instruction Manual

3-5

6

Power Cable

Wire sizes vary based on the distance of the receptacle from the main box. The wire sizes listed in the table above

were taken from the National Electric Code 1990 handbook, table 310.16. Use a 4-conductor Type SO input power

cable with a conductor temperature rating of 140°F (60°C). The cable should be installed only by a licensed

electrician.

Note

:

A lifting eye is provided for moving the power supply into place with a crane or hoist. It may also be moved

by forklift if the forks are long enough to extend the entire length of the base. Take care when lifting with the

forks so that the underside of the power supply is not damaged.

Place the power supply in an area that is free of excessive moisture, has proper ventilation, and is relatively

clean. Allow room for accessing the sides of the power supply for servicing.

• Cooling air is drawn in through the front panel grating, and is exhausted through the rear of the unit by a

cooling fan. Do not place any filter device over the air intake locations. This reduces cooling efficiency and

VOIDS THE WARRANTY.

Positioning the Power Supply

WARNING

Remove all electrical connections to power supply before moving or positioning. Transporting
unit can cause personal injury and equipment damage.

WARNING

The line disconnect switch must be in the OFF position before making the power cable
connections! In the U.S., use a "lock-out/tag-out" procedure until installation is complete. In
other countries, follow appropriate local or national safety procedures.

Connecting the Power