MAINTENANCE

HySpeed HT2000LHF

Instruction Manual

5-9

6

Problem

Possible Causes

/ Solutions

Status LED Troubleshooting

Be certain that the power supply has been through the

Initial Checks

as outlined earlier in this section before

troubleshooting STATUS LEDs.

When any one of the STATUS LEDs illuminates, there is a fault condition that must be corrected in order for the

HT2000LHF power supply to become operational. See

Section 7

in this manual for reference.

1. INTERLOCK LED illuminated:

This LED should never illuminate. Call the Technical Services

department listed in the front of this manual if this LED

illuminates.

2. TRANSFORMER LED illuminated:

2.1. Main Transformer T2 or one of the choppers is overheating.

This LED will extinguish when the main transformer (T2) is

operating in a normal temperature range (under 165° C

(329° F)) and choppers CH1 and CH2 are also operating in

a normal temperature range (under 82° C (180° F)).

• Check the temperature switches (normally closed).

• Check pins, connectors and wiring to temperature

switches.

• Leave the fans running, and try restarting the unit after

one hour. If LED still illuminates, one of the choppers or

the main transformer may need to be replaced.

3. COOLANT LEVEL LED illuminated:

3.1. Coolant level is low.

This LED will extinguish when a proper coolant level in the

coolant reservoir is maintained. Level switch LS1 is located

in the coolant reservoir, and will open when it senses that

coolant level is too low.

• Check the coolant level.

• If the coolant level is adequate, check to see if LS1 switch

is closed.

• Check connections and wiring from LS1 to PCB1.

Repair and/or replace defective component(s), if necessary.