APPENDIX A: ARGON-HYDROGEN CUTTING AND GOUGING

a-2

HySpeed HT2000LHF

Instruction Manual

6

Argon-Hydrogen supply to Argon-Hydrogen Manifold

• Attach one end of the supply hose to the argon-hydrogen supply tank regulator, and attach the other end to

the argon-hydrogen supply hose connection on the manifold. (Figure a-2)

Figure a-2

Argon-Hydrogen Manifold Connection Points

Cable Connection Point

Plasma Gas
Torch Lead
Connection

Argon-Hydrogen
Supply Hose
Connection

Argon-Hydrogen Cable – Argon-Hydrogen Manifold to Power Supply

1. Connect the receptacle end of the argon-hydrogen cable to the cable connection point on the argon-

hydrogen manifold. (Figure a-2)

2. Connect the other end of the cable to TB4 (smaller terminal strip on the inside rear panel of the power

supply). Match up wires 102, 103, 13 and 14 to wires already connected to the strip. Connect the two

shield wires to points labeled as PE (protective earth).

Part No.

Length

023660

15 ft (4.6 m)

023661

25 ft (7.6 m)

023662

50 ft (15 m)

023663

75 ft (23 m)

023664

100 ft (30 m)

023665

150 ft (46 m)

13

13

14X1

13

14

etc.

14x1

TB4

Color

Signal

1

13

Red

PS1 / Plasma

2

14

Black

PS1 / Plasma

12

Shield

Shield

3

102

Green

SV5 / Plasma Off

4

103

Black

SV5 / Plasma Off

9

Shield

Shield