Changed Page

Description

IM304 Rev 4 to 5

9/27/99

0.01

Uprevved because of ECNs 10483, 10484, 10639m, 10145, 10670

0.02

Added plumbing and electrical codes statement to warranty

1.0-1a.06

New safety sections

3.18

New graphic of valve cluster

3.19

Modified graphic of torch

5.17

Changed graphic of coolant reservoir

5.18

New graphic of coolant reservoir

6.08

New coolant reservoir #, new level switch SA #

6.15

New Torch mounting sleeve #

6.18

Added new level switch SA # to recommended spare parts

7.05-7.13

Uprevved wiring diagrams to G

Begin w/serial # 2LHF-000300

Changed Page

Description

IM304 Rev 3 to 4

5/26/99

0.01

Uprevved because of request to add cut quality info and ECNs 10228, 10308, 10344, 10417

0.03-.08

Updated TOC

2.03

Added 440V power supplies

3.03

Changed spec. on coolant

3.04

Added power specs for 440V

3.11

Added note referencing DC relay kit part number

4.10

Added line referencing cutting techniques

4.33-4.36

Adding cutting techniques

6.04

Added 440V control xfrmr

6.05

Added 440V power xfrmr

6.09

Changed p/n of items 6 and 7 for new pressure switch

6.13

Added 015049 to parts list

6.16

Changed figure title to HT2000 Consumable Parts

6.17

Added HT2000 Beveling Consumable Parts Kit

6.18

Bumped page - also changed p/n for pressure switch in gas console recommended spare parts

7.01-7.13

Wiring diagram change to reflect new 440V power supply rev E to rev F

a.01-a.14

Added argon-hydrogen cutting and installation

i.01-i.06

Updated index

Begin w/serial # 2LHF-000199

Changed Page

Description

Rev 5 to 6

8/31/03

6.2

Item # 7 changed from 041560 to 041764. Item # 8 081031 (firmware)

was removed.

Section 7 Wiring diagram revision changed from H to K (all pages)