Operation, English, Metric – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual

Page 104: Stainless steel – 3" under water 100 amps, Air plasma / air shield

Advertising
background image

MAX200

Instruction Manual

4-39

15

OPERATION

Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test
(psi)

Run

(psi)

(psi)

(Inches)

(Inches)

(mm)

(Volts)

(ipm)

(mm/min)

(sec)

1/8

5/64

2

125

135

3400

0.0

3/16

1/8

3

130

100

2520

0.5

1/4

1/8

3

135

65

1720

0.5

3/8

1/8

3

140

45

1120

0.5

1/2

1/8

3

145

25

670

*

Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test

(bar)

Run

(bar)

(bar)

(mm)

(mm)

(Inches)

(Volts)

(mm/min)

(ipm)

(sec)

3

2

5/64

125

3400

135

0.0

5

3

1/8

130

2520

100

0.5

6

3

1/8

135

1720

65

0.5

10

3

1/8

140

1120

45

0.5

12

3

1/8

145

670

25

*

English

Plasma

Gas

Flowrate

(SCFH)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(SCFH)

Torch-to-Work

Distance

Travel Speed

37

22-26

54-58

280

70

Metric

Plasma

Gas

Flowrate

(l/min)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(l/min)

Torch-to-Work

Distance

Travel Speed

17

1.5-1.8

3.7-4.0

132

4.8

Stainless Steel – 3" Under Water

100 amps

Air Plasma / Air Shield

This gas combination gives good cut speed, low dross levels and is very economical. Some surface
nitriting and surface oxidation of alloying elements can occur.

Set plasma gas inlet pressure to 90 psi (6.2 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
* Production cutting above 3/8 inch (10 mm) not recommended.

020448

Shield

020611

Nozzle

020423

Retaining cap

120547

Electrode

020607

Swirl ring

Advertising