3-10

MAX200

Instruction Manual

14

SETUP

220/380/400/415V Transformer T1 and T2 Configurations

• The 220/380/400/415-volt, 3Ø, 50 Hz power supply is normally shipped from the factory set up for 380-volt

operation, unless otherwise specified. To change the power supply to a different voltage, control transformer
T1 and 30 kw transformer T2 must be reconfigured (see Figure 3-2)

WARNING

Danger: High Voltage. Line voltage is present in the power supply unless disconnected.
Always disconnect input power at the line disconnect switch before servicing.

T2

T1

220

380

T1

T2

* A long # 6 wire is shipped with every unit.

Figure 3-2

220/380/400/415V Transformer T1 and T2 Configurations (1 of 2)