Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test
(psi)

Run

(psi)

(psi)

(Inches)

(Inches)

(mm)

(Volts)

(ipm)

(mm/min)

(sec)

1/4

1/8

3

130

130

3300

0.5

3/8

1/8

3

135

95

2400

1.0

1/2

1/8

3

140

75

1900

2.0

5/8

.16

4

145

50

1200

2.0

3/4

3/16

5

150

35

850

2.5

7/8

1/4

6

155

20

530

3.0

1

1/4

6

165

15

400

3.0

Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test

(bar)

Run

(bar)

(bar)

(mm)

(mm)

(Inches)

(Volts)

(mm/min)

(ipm)

(sec)

6

3

1/8

130

3300

130

0.5

8

3

1/8

135

2700

110

0.5

10

3

1/8

135

2400

95

1.0

12

3

1/8

140

1900

75

2.0

15

4

.16

145

1200

50

2.0

20

5

3/16

150

850

35

2.5

25

6

1/4

165

400

15

3.0

English

Plasma

Gas

Flowrate

(SCFH)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(SCFH)

Torch-to-Work

Distance

Travel Speed

66

44-48

58-62

280

70

Metric

Plasma

Gas

Flowrate

(l/min)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(l/min)

Torch-to-Work

Distance

Travel Speed

31

3.0-3.3

4.0-4.3

132

4.8

Mild Steel – 3" Under Water

200 amps

Air Plasma / Air Shield

This gas combination gives good cut speed, low dross levels and is very economical. Some surface
nitriting can occur.

Set plasma gas inlet pressure to 90 psi (6.2 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.

020424

Shield

020608

Nozzle

020423

Retaining cap

220021

Electrode

020607

Swirl ring

Advertising
This manual is related to the following products: