OPERATION

Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test
(psi)

Run

(psi)

(psi)

(Inches)

(Inches)

(mm)

(Volts)

(ipm)

(mm/min)

(sec)

1/8

3/32

2.5

125

140

3560

0.0

3/16

1/8

3

130

110

2800

0.5

1/4

1/8

3

130

80

2030

0.5

3/8

1/8

3

135

55

1400

0.5

1/2

1/8

3

140

35

890

*

5/8

.16

4

145

25

635

*

3/4

3/16

5

150

20

510

*

Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test

(bar)

Run

(bar)

(bar)

(mm)

(mm)

(Inches)

(Volts)

(mm/min)

(ipm)

(sec)

3

2.5

3/32

125

3560

140

0.0

5

3

1/8

130

2800

110

0.5

6

3

1/8

130

2030

80

0.5

10

3

1/8

135

1400

55

0.5

12

3

1/8

140

890

35

*

15

4

.16

145

635

25

*

20

5

3/16

150

510

20

*

Metric

Plasma

Gas

Flowrate

(l/min)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(l/min)

Torch-to-Work

Distance

Travel Speed

37

22-26

54-58

270

60

English

Plasma

Gas

Flowrate

(SCFH)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(SCFH)

Torch-to-Work

Distance

Travel Speed

17

1.5-1.8

3.7-4.0

127

4.0

Stainless Steel – Above Water

100 amps

Air Plasma / Air Shield

This gas combination gives good cut speed, low dross levels and is very economical. Some surface
nitriting and surface oxidation of alloying elements can occur.

Set plasma gas inlet pressure to 90 psi (6.2 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
* Production cutting above 3/8 inch (10 mm) not recommended.

020448

Shield

020611

Nozzle

120837

Retaining cap

120547

Electrode

020607

Swirl ring