Operation, English, Metric – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual

Page 84: Stainless steel – above water 40 amps, Air plasma / air shield

Advertising
background image

MAX200

Instruction Manual

4-19

15

OPERATION

Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test
(psi)

Run

(psi)

(psi)

(Inches)

(Inches)

(mm)

(Volts)

(ipm)

(mm/min)

(sec)

.050 (18GA.)

3/32

2.5

120

145

3700

0.0

1/16

3/32

2.5

120

120

3050

0.0

1/8

3/32

2.5

125

75

1900

0.5

1/4

1/8

3

135

30

750

*

3/8

1/8

3

140

12

300

*

Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test

(bar)

Run

(bar)

(bar)

(mm)

(mm)

(Inches)

(Volts)

(mm/min)

(ipm)

(sec)

3

2.5

3/32

125

1900

75

0.5

6

3

1/8

135

750

30

*

10

3

1/8

140

300

12

*

Torch-to-Work

Distance

Travel Speed

English

Plasma

Gas

Flowrate

(SCFH)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(SCFH)

Torch-to-Work

Distance

Travel Speed

Metric

Plasma

Gas

Flowrate

(l/min)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(l/min)

4.0

25

16-20

56-60

275

60

12

1.1-1.4

3.9-4.1

129

Stainless Steel – Above Water

40 amps

Air Plasma / Air Shield

This gas combination gives good cut speed, low dross levels and is very economical. Some surface
nitriting and surface oxidation of alloying elements can occur.

Set plasma gas inlet pressure to 90 psi (6.2 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
* Production cutting above 3/8 inch (10 mm) not recommended.

020514

Shield

020689

Nozzle

020423

Retaining cap

220021

Electrode

020613

Swirl ring

Advertising