General

This appendix will enable a qualified electrician to install the power cable to the EMI filter on 400V CE power
supplies 073200 (without THC) and 073213 (with THC) for machine torch systems.

Power Cable

The power cable is customer supplied. See Power Cable on pages 3-8 for recommended cable sizes. Final
specification and installation of the power cord should be made by a licensed electrician and according to
applicable national or local codes. See also Mains Supply on page d-2 for further power (supply) cable shielding
recommendations.

Connect power cable

Connect one end of the power cable to the EMI filter first and then connect the other end to the line disconnect
switch.

Power Supply

1. Locate the EMI filter on the top rear of the power supply (see Figure d-1).

Figure d-1

MAX200 Power Supply with EMI Filter – Side View

EMI Filter

Strain Relief

Advertising