SETUP

Install the MAX200 with THC Option

The THC option consists of:

• The THC Subassembly (located in the MAX200)
• The Remote Control Station
• The MAX200 to Remote Control Station interconnection cable.

To install the Remote Control Station and then connect it to the MAX200, perform the following procedures. See
Figure 3-11 to make interconnections.

Mount the Remote Control Station

Mount the required Remote Control Station adjacent to the guidance machinery controls, so that the operator has
convenient access to this unit when operating the system. After mounting the Remote Control Station, the unit is
ready to be connected.

Connect the Remote Control Station to the MAX200

Connect the interface cable from either the Switch Remote (SR), Digital Remote (DR), or Programmable Remote
(PR) receptacle at the rear to the REMOTE V/C - 1X4 receptacle at the rear of MAX200. See Figures 3-12 through
3-14 for cable layouts, cable part numbers and lengths, socket pin configurations, and wire colors and signal
names.

Connect the Programmable Remote to the Computer

If the Programmable Remote is used, connect the computer interface cable from the right rear receptacle to the
computer (see Figure 3-14).

Connect the Cutting Machine to the MAX200

Connect the interface cable from the MACHINE -1X6 receptacle on the MAX200 to the cutting machine interface.
See Figure 3-10 for cable layouts, cable part numbers and lengths, socket pin configurations, and wire colors and
signal names.