MAINTENANCE

Problem:

The green POWER ON indicator is illuminated, the torch switch is pressed and the DC ON
indicator illuminates, and there is high frequency, but there is no pilot arc.

Cause:

There is no high frequency at the torch.

Solution:

Check for a shorted torch, a damaged pilot arc lead, or loose lead connections.
Replace the torch or pilot arc lead or tighten the lead connections.

Cause:

The pilot arc relay CR1 is defective.

Solution:

Replace relay CR1.

Cause:

Control board PCB7 is defective.

Solution:

Replace board PCB7.

Problem:

The unit shuts itself off after it is turned on.

Cause:

The unit has overheated

Solution:

Wait for the unit to cool down.

Cause:

There is insufficient air or gas pressure.

Solution:

Check the gauge on the back panel. Increase the air or gas pressure to the unit.

Cause:

Auxilliary switches on the safety contactor are loose.

Solution:

Tighten the switches.

Problem:

The unit is not cutting well.

Cause:

The work clamp is not connected or it is broken.

Solution:

Connect or repair the work clamp.

Cause:

The torch is cracked.

Solution:

Replace the torch.

Cause:

The pilot arc relay CR1 is defective. Check for contacts that are welded shut

Solution:

Replace relay CR1.