Operation, English, Metric – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual

Page 105: Stainless steel – 3" under water 200 amps, Plasma / air shield

Advertising
background image

4-40

MAX200

Instruction Manual

15

OPERATION

Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test
(psi)

Run

(psi)

(psi)

(Inches)

(Inches)

(mm)

(Volts)

(ipm)

(mm/min)

(sec)

3/16

1/8

3

125

130

3250

0.0

1/4

1/8

3

130

110

2750

0.5

3/8

1/8

3

135

85

2160

1.0

1/2

1/8

3

140

60

1520

2.0

5/8

.16

4

145

45

1140

2.0

3/4

3/16

5

145

30

800

2.5

Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test

(bar)

Run

(bar)

(bar)

(mm)

(mm)

(Inches)

(Volts)

(mm/min)

(ipm)

(sec)

5

3

1/8

125

3250

130

0.0

6

3

1/8

130

2750

110

0.5

10

3

1/8

135

2160

85

1.0

12

3

1/8

140

1520

60

2.0

15

4

.16

145

1140

45

2.0

20

5

3/16

145

800

30

2.5

Torch-to-Work

Distance

Travel Speed

English

Plasma

Gas

Flowrate

(SCFH)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(SCFH)

Torch-to-Work

Distance

Travel Speed

Metric

Plasma

Gas

Flowrate

(l/min)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(l/min)

70

28

2.3-2.6

3.5-3.7

132

4.8

60

34-38

50-54

280

Stainless Steel – 3" Under Water

200 amps

N

2

Plasma / Air Shield

This gas combination is used when cut edge quality, surface nitriting and surface oxidation of alloying
elements are less important. Electrode life is extended when this combination is used.

Set plasma gas inlet pressure to 120 psi (8.3 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.

020424

Shield

020608

Nozzle

020423

Retaining cap

020415

Electrode

020607

Swirl ring

Advertising
This manual is related to the following products: