Install the MAX200 with IHS Option

The IHS option can only be used when the THC option has been installed as described above. The IHS option
consists of:

• The Inductive IHS Control Module

• The Torch Mounting Subassembly

To install the IHS option, perform the following procedures. See Figure 3-15 to make interconnections.

Mount the IHS Control Module

Mount the IHS Control Module on to the cutting machine frame. It must be located within 40 feet of the torch. After
mounting the IHS Control Module, the unit is ready to be connected to the MAX200 and the shop air supply.

Connect to the MAX200

Connect the interface cable from the receptacle at the IHS Control Module to the IHS - 1X9 receptacle at the rear
of MAX200 (see Figure 3-15). Also see Figure 3-16 for the cable layout, cable part numbers and lengths, socket pin
configurations, and wire colors and signal names.

Connect to the Shop Air Supply

1. The customer must supply the 20 psig regulated shop air and the air hose. A #4 swivel fitting (# 015006) is

provided.

2. Attach the swivel fitting to the air hose. Connect this fitting to the air inlet fitting on the IHS Control Module

(see Figure 3-15).

3. Attach the other end of the air hose to the regulated shop air supply.

Mount the Torch Mounting Subassembly

1. Mount the Torch Mounting Subassembly on to the torch lifter of the cutting machine.

2. Mount the machine torch, connect the inductor sensors to the IHS Control Module, and connect the air hose

from the Torch Mounting Subassembly to the IHS Control Module as follows:

Mount the Machine Torch

1. Install the machine torch (with torch lead attached) in the bracket of the Torch Mounting Subassembly (see