240/480v linkboard configurations -9 – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual
Page 37
Advertising
MAX200
Instruction Manual
3-9
14
SETUP
240/480V Linkboard Configurations
• The 240/480-volt unit (# 073002 and # 073020) is shipped from the factory linked for 480-volt operation.
The links must be moved for 240-volt operation. Ensure that the linkboard is configured properly to the
appropriate voltage line (see Figure 3-1).
WARNING
Danger: High Voltage. Line voltage may be present on this linkboard. Disconnect input power
before servicing.
Figure 3-1
Dual Voltage 240/480-Volt Linkboard Configurations
240-Volt Configuration
480-Volt Configuration