Operation, English, Metric – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual

Page 110: Aluminum – 3" under water 200 amps, Plasma / co, Shield

Advertising
background image

MAX200

Instruction Manual

4-45

15

OPERATION

Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test
(psi)

Run

(psi)

(psi)

(Inches)

(Inches)

(mm)

(Volts)

(ipm)

(mm/min)

(sec)

3/16

1/8

3

130

175

4450

0.5

1/4

1/8

3

135

145

3650

1.0

3/8

1/8

3

140

100

2600

2.0

1/2

1/8

3

145

75

1820

2.5

5/8

.16

4

145

55

1350

2.5

3/4

3/16

5

155

40

980

3.0

7/8

1/4

5

165

30

750

3.0

Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test

(bar)

Run

(bar)

(bar)

(mm)

(mm)

(Inches)

(Volts)

(mm/min)

(ipm)

(sec)

5

3

1/8

130

4450

175

0.5

6

3

1/8

135

3650

145

1.0

10

3

1/8

140

2600

100

2.0

12

3

1/8

145

1820

75

2.5

15

4

.16

145

1350

55

2.5

20

5

3/16

155

980

40

3.0

English

Plasma

Gas

Flowrate

(SCFH)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(SCFH)

Torch-to-Work

Distance

Travel Speed

60

36-40

52-56

220

70

Metric

Plasma

Gas

Flowrate

(l/min)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(l/min)

Torch-to-Work

Distance

Travel Speed

28

2.5-2.8

3.6-3.9

103

4.8

Aluminum – 3" Under Water

200 amps

N

2

Plasma / CO

2

Shield

This gas combination is used when cut edge quality is less important. Electrode life is extended when this
combination is used.

Set plasma gas inlet pressure to 120 psi (8.3 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.

020424

Shield

020608

Nozzle

020423

Retaining cap

020415

Electrode

020607

Swirl ring

Advertising
This manual is related to the following products: