Operation, English, Metric – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual
Page 96: Mild steel – gouging 200 amps, Air plasma / air shield
Advertising
MAX200
Instruction Manual
4-31
15
OPERATION
49-51
50-52
50
90
90
3.4-3.5
3.4-3.6
3.4
6.2
6.2
Shield
Gas
Pressure
(psi)
Plasma
Gas Inlet
Pressure
(psi)
TEST
(psi)
RUN
(psi)
English
Shield
Gas Inlet
Pressure
(psi)
Shield
Gas Inlet
Pressure
(bar)
RUN
(bar)
Metric
Plasma Gas Pressure
Shield
Gas
Pressure
(bar)
Plasma
Gas Inlet
Pressure
(bar)
TEST
(bar)
Plasma Gas Pressure
Mild Steel – Gouging
200 amps
•
Air Plasma / Air Shield
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
020485
Shield
020615
Nozzle
020423
Retaining cap
220021
Electrode
020607
Swirl ring
Advertising
This manual is related to the following products: