Operation, English, Metric – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual

Page 96: Mild steel – gouging 200 amps, Air plasma / air shield

Advertising
background image

MAX200

Instruction Manual

4-31

15

OPERATION

49-51

50-52

50

90

90

3.4-3.5

3.4-3.6

3.4

6.2

6.2

Shield

Gas

Pressure

(psi)

Plasma

Gas Inlet
Pressure

(psi)

TEST

(psi)

RUN
(psi)

English

Shield

Gas Inlet
Pressure

(psi)

Shield

Gas Inlet
Pressure

(bar)

RUN
(bar)

Metric

Plasma Gas Pressure

Shield

Gas

Pressure

(bar)

Plasma

Gas Inlet
Pressure

(bar)

TEST

(bar)

Plasma Gas Pressure

Mild Steel – Gouging

200 amps

Air Plasma / Air Shield

If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.

020485

Shield

020615

Nozzle

020423

Retaining cap

220021

Electrode

020607

Swirl ring

Advertising
This manual is related to the following products: