Operation, Metric, English – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual

Page 95: Aluminum – above water 100 amps, H35 plasma / n, Shield, Warning

Advertising
background image

4-30

MAX200

Instruction Manual

14

OPERATION

Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test
(psi)

Run

(psi)

(psi)

(Inches)

(Inches)

(mm)

(Volts)

(ipm)

(mm/min)

(sec)

1/8

3/32

2.5

135

95

2440

0.0

3/16

1/8

3

140

85

2200

0.5

1/4

1/8

3

145

80

1980

0.5

3/8

1/8

3

145

60

1530

0.5

1/2

1/8

3

150

50

1280

*

Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test

(bar)

Run

(bar)

(bar)

(mm)

(mm)

(Inches)

(Volts)

(mm/min)

(ipm)

(sec)

3

2.5

3/32

135

2440

95

0.0

5

3

1/8

140

2200

85

0.5

6

3

1/8

145

1980

80

0.5

10

3

1/8

145

1530

60

0.5

12

3

1/8

150

1280

50

*

Torch-to-Work

Distance

Travel Speed

9

2.2-2.5

3.9-4.1

127

4.0

Metric

Plasma

Gas

Flowrate

(l/min)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(l/min)

Torch-to-Work

Distance

Travel Speed

20

32-36

56-60

270

60

English

Plasma

Gas

Flowrate

(SCFH)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(SCFH)

Set plasma gas inlet pressure to 120 psi (8.3 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
* Production cutting above 3/8 inch (10 mm) not recommended.

Aluminum – Above Water

100 amps

H35 Plasma / N

2

Shield

This gas combination gives good cut speed, low dross levels and is very economical.

WARNING

Do not use water muffler when
cutting with argon-hydrogen!

020448

Shield

020611

Nozzle

120837

Retaining cap

020415

Electrode

020607

Swirl ring

Advertising
This manual is related to the following products: