Operation, English, Metric – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual

Page 108: Aluminum – 3" under water 100 amps, Air plasma / air shield

Advertising
background image

MAX200

Instruction Manual

4-43

15

OPERATION

Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test
(psi)

Run

(psi)

(psi)

(Inches)

(Inches)

(mm)

(Volts)

(ipm)

(mm/min)

(sec)

1/8

5/64

2

135

100

2650

0.0

3/16

1/8

3

140

80

2050

0.5

1/4

1/8

3

145

60

1510

0.5

3/8

1/8

3

150

40

1000

0.5

1/2

1/8

3

155

30

750

*

Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test

(bar)

Run

(bar)

(bar)

(mm)

(mm)

(Inches)

(Volts)

(mm/min)

(ipm)

(sec)

3

2

5/64

135

2650

100

0.0

5

3

1/8

140

2050

80

0.5

6

3

1/8

145

1510

60

0.5

10

3

1/8

150

1000

40

0.5

12

3

1/8

155

750

30

*

English

Plasma

Gas

Flowrate

(SCFH)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(SCFH)

Torch-to-Work

Distance

Travel Speed

37

22-26

54-58

280

70

Metric

Plasma

Gas

Flowrate

(l/min)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(l/min)

Torch-to-Work

Distance

Travel Speed

17

1.5-1.8

3.7-4.0

132

4.8

Aluminum – 3" Under Water

100 amps

Air Plasma / Air Shield

This gas combination gives good cut speed, low dross levels and is very economical.

Set plasma gas inlet pressure to 90 psi (6.2 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
* Production cutting above 3/8 inch (10 mm) not recommended.

020448

Shield

020611

Nozzle

020423

Retaining cap

120547

Electrode

020607

Swirl ring

Advertising
This manual is related to the following products: