15

OPERATION

Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test
(psi)

Run

(psi)

(psi)

(Inches)

(Inches)

(mm)

(Volts)

(ipm)

(mm/min)

(sec)

3/16

1/8

3

135

170

4350

0.5

1/4

1/8

3

140

140

3650

1.0

3/8

1/8

3

140

100

2600

1.5

1/2

1/8

3

145

65

1620

2.0

5/8

.16

4

145

55

1350

2.5

3/4

3/16

5

155

35

890

3.0

7/8

1/4

5

165

25

620

3.0

Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test

(bar)

Run

(bar)

(bar)

(mm)

(mm)

(Inches)

(Volts)

(mm/min)

(ipm)

(sec)

5

3

1/8

135

4350

170

0.5

6

3

1/8

140

3650

140

1.0

10

3

1/8

140

2600

100

1.5

12

3

1/8

145

1620

65

2.0

15

4

.16

145

1350

55

2.5

20

5

3/16

155

890

35

3.0

English

Plasma

Gas

Flowrate

(SCFH)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(SCFH)

Torch-to-Work

Distance

Travel Speed

60

34-38

50-54

280

70

Metric

Plasma

Gas

Flowrate

(l/min)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(l/min)

Torch-to-Work

Distance

Travel Speed

28

2.3-2.6

3.4-3.7

132

4.8

Aluminum – 3" Under Water

200 amps

N

2

Plasma / Air Shield

This gas combination is used when cut edge quality is less important. Electrode life is extended when this
combination is used.

Set plasma gas inlet pressure to 120 psi (8.3 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.