Operation, English, Metric – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual

Page 91: Aluminum – above water 40 amps, Air plasma / air shield

Advertising
background image

4-26

MAX200

Instruction Manual

15

OPERATION

Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test
(psi)

Run

(psi)

(psi)

(Inches)

(Inches)

(mm)

(Volts)

(ipm)

(mm/min)

(sec)

3/32

3/32

2.5

120

140

3550

0.0

1/8

3/32

2.5

130

100

2550

0.5

1/4

1/8

3

140

35

900

*

3/8

1/8

3

150

15

350

*

Shield

Gas

Pressure

Material

Thickness

Arc

Voltage

Setting

Approx.

Motion

Delay Time

Test

(bar)

Run

(bar)

(bar)

(mm)

(mm)

(Inches)

(Volts)

(mm/min)

(ipm)

(sec)

3

2.5

3/32

130

2550

100

0.5

6

3

1/8

140

900

35

*

10

3

1/8

150

350

15

*

Torch-to-Work

Distance

Travel Speed

English

Plasma

Gas

Flowrate

(SCFH)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(SCFH)

Metric

Plasma

Gas

Flowrate

(l/min)

Plasma Gas

Pressure

Shield

Gas

Flowrate

(l/min)

Torch-to-Work

Distance

Travel Speed

12

1.1-1.4

3.9-4.1

129

4.0

60

25

16-20

56-60

275

Aluminum – Above Water

40 amps

Air Plasma / Air Shield

This gas combination gives good cut speed, low dross levels and is very economical.

Set plasma gas inlet pressure to 90 psi (6.2 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
* Production cutting above 1/8 inch (3 mm) not recommended.

020514

Shield

020689

Nozzle

020423

Retaining cap

220021

Electrode

020613

Swirl ring

Advertising
This manual is related to the following products: