TASCAM MMP-16 Owner’s Manual • Appendix H • MMC Protocol

156

MMP-16 MMC Signature

2E,

count = n

01, 00, 00, 00,

vi vf va vb

14,

<count_1>

7E, 5D, 00, 00, 00, c0 c1 c2 c3 c4
00, 00, 00, 00, 00,

c5 c6 c7 c8 c9

71, 31, 50, 00, 00,

c10 c11 c12 c13 c14

00, 00, 00, 00, 00,

c15 c16 c17 c18 c19

14,

<count_2>

7E, 7E, 03, 00, 00, r0 r1 r2 r3 r4
7E, 7E, 03, 00, 00, r5 r6 r7 r8 r9
25, 66, 0F, 28, 04, r10 r11 r12 r13 r14
00, 00, 00, 00, 00, r15 r16 r17 r18 r19

MIDI Inquiry Message

General Response: F0 7E <channel> 06 02 mm ff ff dd dd ss ss ss ss F7

The MMR-8 and MMP-16 engineering development is done by TimeLine Vista, Inc. The MIDI inquiry
response codes are therefore those of TimeLine and not TASCAM.

The MMR-8 responds to a MIDI Inquiry message as follows:

mm

TimeLine manufacturer system exclusive ID

00 00 49

ff ff

Device Family Code

04 00 (LSB First)

dd dd

Device Family Member Code

00 00 (LSB First)

ss ss ss ss

Software Revision Level

00 00 xx xx (e.g. 03 00)

The MMP-16 responds to a MIDI Inquiry message as follows:

mm

TimeLine manufacturer system exclusive ID

00 00 49

ff ff

Device Family Code

04 00 (LSB First)

dd dd

Device Family Member Code

01 00 (LSB First)

ss ss ss ss

Software Revision Level

00 00 xx xx (e.g. 03 00)