Page 134: Voice path configuration -60

Advertising
background image

4-60

8 0 0 0 S e r i e s

2

Type the forward delay value and press Enter. The IAD updates the
configuration.

3

Press any key to return to the Bridge Configuration menu and continue with
other configuration tasks.

Configure Spanning Tree Path Cost

When there are multiple paths to the Root Bridge, the Spanning Tree
algorithm selects the port with the lowest total path cost as the route port.

To set the Spanning Tree path cost (a value between 1 and 65,535—default
32,768), follow the steps below.

1

Type “C” on the Bridge Configuration menu to select Configure Spanning
Tree Path Cost.The IAD displays the interfaces available on this IAD as
shown in Figure 4.60.

2

Type the interface number. The IAD displays a port table. If more than one
interface is configured on the selected port, the IAD displays a list of
interfaces:

3

Type the number of the port. The IAD displays the current setting and
prompts you to enter the Path Cost for the selected Slot and Port.

4

Type the path cost value and press Enter. The IAD updates the
configuration.

5

Press any key to return to the Bridge Configuration menu and continue with
other configuration tasks.

Delete Bridge Forwarding Database Entry

To delete an Ethernet address from the bridge forwarding database, follow the
steps below.

1

Type “D” on the Bridge Configuration menu (Figure 4.69) to select Delete
Bridge Forwarding Database Entry. The IAD prompts you to enter the
Ethernet address.

2

Type the MAC address of the Ethernet port and press Enter. The IAD
deletes the database entry and updates the configuration.

3

Press any key to return to the Bridge Configuration menu and continue with
other configuration tasks.

Voice Path Configuration

After you have defined the voice PVCs or DLCIs on the IAD, configure the
voice path for voice operation.

NOTICE:

When the IAD prompts you for input, the current value is displayed in
parentheses. To conveniently accept the current value, just press Enter.

Advertising