DtSet

Date

20060101 to

20991231

yyyymmdd

ExlStrStpEna*

Activation of external shutdown signal/

remote shutdown

Off

Deactivated

Off

On

Activated

ExlTrfErrEna*

Activation of hermetic protection of MV

transformer

Off

Deactivated

On

On

Activated

ExtSolIrrOfs

Offset of the external irradiation sensor − 5,000 W/m

2

to 5,000 W/m

2

0 W/m

2

ExtSolIrrGain

Amplification of external irradiation

sensor

− 1,000 W/m

2

to 1,000 W/m

2

1

GdErrTm*

Grid monitoring time after grid error

0 s to 10,000 s ‒

300 s

GdChkTm*

Grid monitoring time after system start

0 s to 10,000 s ‒

300 s

MppFact

Ratio between maximum power P

MPP

of

the PV cell at the maximum power point

and the product of open-circuit voltage

V

OC

and short-circuit current I

SC

0.5 to 1

0.8

Ofs_h-On***

Offset for operating hours

0 h to

2,147,482 h

0

Ofs_h-Total***

Offset for feed-in hours

0 h to

2,147,482 h

0

Ofs_E-Total***

Offset for total supplied energy

0 kWh to

214,748,367

kWh

0

Ofs_CntFanHs*

Offset for operating hours of heat sink

fan

0 h to

2,147,482 h

0

Ofs_CntFanCab1* Offset for operating hours of internal fan

1

0 h to

2,147,482 h

0

Ofs_CntFanCab2* Offset for operating hours of internal fan

2

0 h to

2,147,482 h

0

Ofs_CntHtCab1*

Offset for operating hours of internal

heating element 1

0 h to

2,147,482 h

0

Ofs_CntHtCab2*

Offset for operating hours of internal

heating element 2

0 h to

2,147,482 h

0

PvPwrMinTr

Threshold for starting the MPP tracker

0 kW to 20 kW ‒

20 kW

PvPwrMinTrT

Timeout for starting the MPP tracker

1 s to 1,800 s ‒

600 s

PvVtgStrLevMin*

Threshold for switching to feed-in

operation

0 V to 1,200 V SC 500CP-JP

410 V

0 V to 1,200 V SC 630CP-JP

610 V

0 V to 1,200 V SC 800CP-JP

760 V