12.3 Sunny String-Monitor

Name

Description

Value/range

Explanation

Default

value

TMittelung*

Duration of measured current

value averaging

0 s to 6 000 s

30 s

String number*

Number of detected PV strings

0 to 8

0

SW version

Current firmware version

1 to 40

Value cannot be

changed

SSM Identifier*

Identification number of

Sunny String-Monitor

1 to 99

0

Group String 1*

Assigns PV strings to their

respective group

0 to 3

Parameter exists for all

eight groups

0

Group String*

All groups

0 to 3

0

No.of String 1*

Number of connected strings in

the respective group

1 to 4

Parameter exists for all

eight groups
Contact the SMA Service

Line if you wish to use this

function.

No.of Strings*

All groups

1 to 4

Monitoring1 On*

Start of monitoring of PV strings

in group 1

0:00 a.m. to

11:59 p.m.

Parameter exists for all

eight groups
Configuration of the

string settings via the

Sunny Central

String-Monitor Controller

is preferable.

0

Monitoring1 Off*

End of monitoring of PV strings in

group 1

0:00 a.m. to

11:59 p.m.

Parameter exists for all

eight groups
Configuration of the

string settings via the

Sunny Central

String-Monitor Controller

is preferable.

0

Monitoring On*

Start of monitoring of PV strings

in all groups

0:00 a.m. to

11:59 p.m.

0

Monitoring Off*

End of monitoring of PV strings in

all groups

0:00 a.m. to

11:59 p.m.

0