12  Parameters

SMA Solar Technology AG

104

SCCP-JP-BA-A4-en-12

User Manual

MoniTmComOn*

Start time for monitoring of all

groups

7:00 a.m. to

7:00 p.m.

10:00

a.m.

MoniTmComOff*

Stop time for monitoring of all

groups

7:00 a.m. to

7:00 p.m.

3:00 p.m.

Ackn

Acknowledge errors

quit

ErrLevGr1*

Sensitivity of error detection for

group 1
Parameter exists for all six

groups

24 Sensitive

50 min ‒ 10%

32

Regular

24 Regular

50 min ‒ 14%

24 Insensitive

50 min ‒ 18%

32 Sensitive

35 min ‒ 10%

32 Regular

35 min ‒ 13%

32 Insensitive

35 min ‒ 16%

64 Sensitive

15 min ‒ 7%

64 Regular

15 min ‒ 9%

64 Insensitive

15 min ‒ 10%

ComBaud*

Baud rate

1,200 Bd

Parameter can only be

changed in the operating

state "Stop".

19,200

Bd

4,800 Bd
9,600 Bd

19,200 Bd
38,400 Bd
57,600 Bd

DevFunc*

Manages the

Sunny String-Monitors

AutoDetect_SSMU

Searches for all

Sunny String-Monitors

and deletes previously

detected Sunny

String-Monitors

0

DetectSSMURetry

Searches for undetected

Sunny String-Monitors

only

DelAll_SSMU

Deletes all detected

Sunny String-Monitors

Factory

Resets all parameters to

default settings

* To change these parameters, you must enter the installer password.

Name

Description

Value/range

Explanation

Default

value