3 displaying the status of active power limitation – SMA SC 500CP-10-JP User Manual

Page 52

Advertising
background image

8  Power Control

SMA Solar Technology AG

52

SCCP-JP-BA-A4-en-12

User Manual

8.1.2.6 Active Power Limitation via Standard Signal: WCnstNomAnIn Mode

The active power limitation is set at the input terminals for setpoint specification using an analog signal (see Sunny Central

installation manual). This is usually implemented by a ripple control signal.
The electrical current strength of the connected signal determines the nominal active power.
The analog measured values must be between 4 mA and 19 mA. If the analog signal is less than 2 mA, an error message

will be displayed in the instantaneous value P-WModFailStt (see Section 8.1.4, page 52).

The analog value is converted to a setpoint for power limitation. Here, the parameter Pmax forms the end point of the

linear characteristic curve.

8.1.3 Displaying the Status of Active Power Limitation

The instantaneous value P-WModStt indicates the status of active power limitation.

Procedure:

• Display the instantaneous value P-WModStt on the user interface (see Section 6.1, page 40).

8.1.4 Displaying Error Messages and Warnings for Active Power Limitation

The instantaneous value P-WModFailStt displays errors or warnings associated with active power limitation.

Procedure:

• Display the instantaneous value P-WModFailStt on the user interface (see Section 6.1, page 40).

Signal

Power limit

Description

< 2 mA

Last valid value or Pmax

after restart

Signal is in the invalid range.

2 mA to 4 mA

0 kW

No power is fed into the grid.

4 mA to 19 mA

0 kW to Pmax

The energy fed into the grid is determined by a characteristic curve.

> 19 mA

Pmax

The power fed into the grid equals Pmax.

Display

Description

Off

No mode for active power limitation has been selected.

WMax

Active power is limited by specification of an upper limit. This limit is relative to Pmax.

Hz

Active power is limited by a frequency increase.

Tmp

Active power is limited by temperature derating.

AmpPv

Active power is limited via a DC current limitation.

AmpAC

Active power is limited via an AC current limitation.

Display

Cause and corrective measure

Off

No mode for active power limitation has been selected.

OK

A mode for active power limitation has been selected and there are no errors present.