INSTALLATION

WARNING

Disconnect from supply before opening enclosure. Keep cover tight while circuits are
alive. Conduit seals must be installed within 18" (450mm) of the enclosure.


Wiring connectors are accessed by opening the enclosure. To access electrical connectors, remove the 2
captive screws, then disconnect the ribbon cable from the display module and set the display module
aside.

Unpacking

Remove the scanner from box. Inspect the packaging and contents for damage. Report damages, if any,
to the carrier. If any part is missing or the scanner malfunctions, please contact your supplier or the
factory for assistance.

Pre-Installed Conduit/Stopping Plug

The PD6730X typically includes three ¾" NPT threaded conduit openings and two ¾" NPT plastic conduit
plugs, with 1.29" wrenching flats and a screwdriver slot, installed. Additional conduit opening configura-
tions and plugs may be available; verify quantity and sizes on specific device labeling during installation.
The conduit/stopping plugs included in a typical PD6730X have an external 32 mm hexagonal socket
pattern for removal.

Mounting

The PD6730X has two slotted mounting flanges that may be used for pipe mounting or wall mounting.
Alternatively, the unit may be supported by the conduit using the conduit holes provided.
Refer to Mounting Dimensions, page 97 for details.

WARNING

Do not attempt to loosen or remove flange bolts while the scanner is in service.

CAUTION

Excess torque may damage the threads and/or wrench.