PD6730X Vantageview Super Snooper Modbus Scanner

Instruction Manual

81

IMPORTANT

Did you forget the passwords?
The password may be disabled by entering a master password. If you are authorized to
make changes, enter the master settings lockout (PASS) password 50865, the master
total reset (PASS T) password 80034, or the master grand total reset (PASS GT)
password 80034 to unlock the scanner.

Non-Resettable Grand Total

The grand total may be configured to be a non-resettable grand total. This is a permanent setting.
Configuring the grand total as a non-resettable grand total locks out all setup parameters that could be
used to reset the grand total or change the setup of the grand total; including pulse input selection, rate
scaling, and conversion factors.
To configure the meter for non-resettable grand total mode, enter the non-resettable grand total password
below into the Pass GT (PASS GT) parameter in the Password (PASS) menu.
The non-resettable grand total permanently locks the following parameters from being changed: pulse
input selection, K-factor, K-factor units, grand total units, grand total conversion factor, grand total decimal
point, scaling, calibration, grand total alarms, pulse input filter, and cutoff.

CAUTION

Locking the meter into a non-resettable grand total is not reversible. It is a permanent
meter configuration. Doing so will permanently prevent most pulse input parameters
from being altered. This should be the last step after verifying all setup parameters.


Non-resettable grand total password: 50873

Non-Resettable Grand Total Locked Menus & Parameters

Display

Parameter/Menu

Action/Setting Locked

PULSE

.IN

Pulse Input

All Pulse Input type selection menu parameters

GTOT U

Grand Total Units

Set grand total units

GT-CF

Grand Total Conversion Factor

Enter the Grand Total Conversion Factor menu

GRTOT.DP

Grand Total Decimal Point

Enter the grand total display decimal point

KFACTOR

K-Factor

All K-Factor menu parameters

sCalE

Scale

All Scale menu parameters

Pass GT

Password Grand Total

Enter the grand total reset password

GRTOT

Grand Total Alarm

All grand total alarm output menu parameters

FILTER

Filter

Enter Filter parameter

CUTOFF

Low-Flow Cutoff

Enter Low-Flow Cutoff parameter

The above menus remain accessible; however the parameters listed above within the menus are locked
and may not be changed.