MVI69-PDPMV1 ♦ CompactLogix or MicroLogix Platform

Diagnostics and Troubleshooting

PROFIBUS DPV1 Master

User Manual

ProSoft Technology, Inc.

Page 149 of 225

July 8, 2011

If there is no response from the module, follow these steps:

1 Click to configure the connection. On the Connection Setup dialog box, select

a valid com port or other connection type supported by the module.

2 Verify that the null modem cable is connected properly between your

computer’s serial port and the module. A regular serial cable will not work.

3 On computers with more than one serial port, verify that your communication

program is connected to the same port that is connected to the module.

If you are still not able to establish a connection, contact ProSoft Technology for
assistance.