Reference MVI69-PDPMV1

♦ CompactLogix or MicroLogix Platform

User Manual

PROFIBUS DPV1 Master

Page 176 of 225

ProSoft Technology, Inc.

July 8, 2011

Word Offset

Start End Name

Description

8 Module alarm CON

receive counter

Number of confirmation messages received from
slaves indicating that the slave received the
confirmation message from the MVI69-PDPMV1
module

9 Module acyclic

Read request
message counter

Number of acyclic read request messages sent by
the module

10 Module acyclic

Write request
message counter

Number of acyclic write request messages sent by
the module

11 Module backplane

read count

Rollover counter of the number of MVI69-PDPMV1
to processor backplane read data transfers

12 Module backplane

write count

Rollover counter of the number of MVI69-PDPMV1
to processor backplane write data transfers

13 Module backplane

error count

Rollover counter of the number of MVI69-PDPMV1
to processor backplane data transfers that have
failed

14

File Error Word

This is bitmapped value that indicates which files are
not present.
Bit 0: Problem with PDPMV1.CFG file
Bit 1: Problem with WATTCP.CFG file
Bit 2: Problem with PDPMV1.DDB file
Bit 3: Problem with PDPMV1.XML file
Bits 4 to 15 not used.
If this word has a value other than 0, the CFG ERR
LED on the module will be illuminated.

15 27 Not

used

28 28 In mailbox queue

count

Number of message in the in mailbox queue

29 29 Out mailbox queue

count

Number of message in the out mailbox queue

30

30

Alarm queue count Number of message in the alarm queue

31 31 Last out mailbox

message ID
processed from
output image

Last out mailbox message ID processed from output
image

32 32 Current in mailbox

control index

Current in mailbox control index

33 33 Current alarm

control index

Current alarm control index

34

60

Reserved

Reserved for future use