Saving provisioning data, Provisioning record, Table 4-4 – Symmetricom EDGE CLOCK 1000 User Manual

Page 141

Advertising
background image

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 141

Chapter 4 Provisioning the TimeProvider

Saving Provisioning Data

Saving Provisioning Data

Symmetricom recommends that you keep an electronic version and/or a written
version of the provisioning changes you make to the TimeProvider.

Electronically Backing up Provisioning Data
Copy the contents of the IOC into the IMC memory by issuing the CPY-MEM
command as follows. See the TimeProvider TL1 Reference Guide for more
information on the CPY-MEM command.

CPY-MEM:::TS1000::IOC,IMC,IOC;

Copy the contents of the IMC into the IOC memory by issuing the CPY-MEM
command as follows:

CPY-MEM:::TS1000::IMC,IOC,IMC;

This command may take more than two seconds to execute; if it does, then the
In-Process response is issued. This command also logs off all users connected to
the TimeProvider.

If two IOCs are in the shelf, the Active IOC automatically saves its data in the
Standby IOC.

Provisioning Worksheet
Use

Table 4-4

to

record the values you provisioned into the TimeProvider.

Table 4-4. Provisioning Record

Section

Parameter

User-Defined Value

Setting the Source ID <sid>

, on page 90

Source ID (<sid>)

Setting RS-232 Parameters

, on page 91

Baud rate

Handshaking mode

Echo mode

Setting Ethernet Parameters

, on page 93

IP Gate address

IP address

Subnet mask

Setting the System Mode

, on page 105

System mode

Setting the IOC Parameters

, on page 107

Oscillator type, IOC1

Oscillator type, IOC2